Description
HYDAC safety and shut-off blocks are designed to protect,
shut-off, and discharge hydraulic accumulators or user
units. The compact design simplifies the hydraulic system
connection and offers the following advantages:
minimum space compared to individual components
reduced installation time
various system connections
system lockout
Safety
& Shut-off Block Features:
1 pressure relief valve
2 pressure gauge (optional)
3 main shut-off valve
4 manual bleed valve
5 2-way solenoid operated bleed valve (optional)
|
Construction
The Safety and Shut-off Block consists of a valve block,
a built-in pressure relief valve, a main shut-off valve,
and a man-ually operated bleed valve. In addition, an
optional solenoid operated bleed valve allows automatic
release of the accumu-lator or user unit and therefore
of the hydraulic system in an emergency or during shut-down.
The necessary return line connection is provided in
addition to the gauge connection.
|
Technical
Specifications
Fluids
Mineral oil, hydraulic oil, water glycol, non-flammable
fluids (other fluids upon request)
Temperature
(for carbon steel)
5º F to 180º F (-15º C to 80º C)
Maximum
Working Pressure
up to 5800 psi (400 bar) Q (l/min) 30 100 80 60 40 20
0 120
|