User
Benefits
- Simple,
Cost-effective way to provide component protection with
minimal space requirements.
-
Provides back-up filtration when upstream filters go
into by-pass or if element damage occurs.
-
Both models use standard manifold cavities
Note: CP filters are designed to provide
final protection to individual components, NOT as total
system filters
|
CP-C16

|
CP-SAE
 |
| Specifications: |
CP-C16
|
CP-SAE
|
| Max.
Operating Pressure |
3,000
psi
|
6,000 psi
|
| Max. Flow Rating |
12 gpm
|
size 15: 4 gpm
size 40: 12 gpm
size 120: 30 gpm
|
| Operating Temperature Range |
-60°F to 250°F
|
-60°F to 250°F
|
| Filtration Rating |
10, 75, or 141µm
nominal
|
10, 75, or 141µm*
nominal
|
| Port Type |
No. C16-2 Port
|
SAE O-ring Port
|
| Weight |
0.65 lbs.
|
size 15: 0.25 lbs.
size 40: 0.50 lbs.
size 120: 1.15 lbs.
|
| Flow Path |
Inside to Out
|
Inside to Out
|
| Bypass Cracking Pressure |
No Bypass
|
50 psi
|
| Fluid Compatibility |
petroleum based fluids |
Petroleum based fluids, water glycol, phosphate esters, diesel fuel,
and gasoline(except if it contains alcohol) |
| *Consult Factory for 75 or 141 element options |
Download CP-C16 Brochure
(50KB) |
Download CP-SAE Brochure
(70KB)